Andatech AlcoSense Precision

User Rating:  / 0
PoorBest 
Do not allow samples containing smoke, tobacco or other chemical products to enter the unit, as damage to the fuel cell can occur.

PREPARATION

1.    Remove the Battery Holder by gently and pull down the battery compartment cover.
2.    Insert fresh an alkaline battery or four AAA size batteries into the Battery Holder, first checking that the + and -on each battery are aligned according to the polarity diagram inside the Battery Holder.
3.    Careful close back the battery compartment cover.

OPERATING INSTRUCTION

NORMAL OPERATION
1.    Insert the disposable mouthpieces to the unit. The mouthpieces can be inserted from both sides of the AlcoSense® PRECISION.
2.    Press and hold the ON/OFF button(3) for 2-3 seconds to turn the unit on
3.    When the LCD display reads BLOW , user should take a deep breath and blow into the mouthpiece for at least 4 seconds. Continue blowing until the beep stops and you hear a click.
4.    When the LCD display reads  WAIT the data is processing. When the process is complete the unit emits several beep tones and displays the reading on the LCD.
5.    The next test can be performed by pressing the ON/OFF button once.
Note: For accurate results, if the alcohol content of the previous test is higher than zero, please wait for 3 minutes before performing the next test.
6.    To turn off the AlcoSense® PRECISION, press and hold the ON/OFF button for 2-3 seconds until several beep tones are heard.
7.    The unit will automatically turn off after 2 minutes without use.

FAST OPERATION
No mouthpieces are required for this method, however is not as accurate as normal operating methods.
1.    Press and hold the ON/OFF button for 2-3 seconds to turn on the unit
2.    When the LCD reads BLOW , user should take a deep breath and blow into the hole for 3 seconds.
3.    Whilst continuing to blow press the functions button to take breath sample. A breath sample will be completed, you will also her a click, which is normal.
4.    When the LCD display reads  WAIT the data is processing. When the reading is ready the unit emits several beep tones and displays reading on the LCD.
5.    To test again straight away, press the ON/OFF button and repeat from steps 1.
6.    If a more accurate reading is required Andatech recommends using a mouth piece and normal operation mode.

MEASUREMENTS AND CONDITIONS FOR TEST

•    Use a new mouthpiece for each test.
•    There must be an interval of at least 15 minutes after alcohol has been taken into the mouth. Residues of alcohol in the mouth may give false measurements. Such residue may be left by aromatic drinks, mouthwash, medicines, and drops, as well as by belching and vomiting. Rinsing out your mouth will water or non-alcoholic drinks do not substitute for an interval.
•    BAC can continue to rise for up to 2 hours after drinking alcohol.  If a caution result or a result is close to designated BAC, it is recommended to wait and retest after 20 minutes.
•    It can take 10 hours or more for the alcohol level to return to a zero after a high blood alcohol level has been reached.  A further test should be carried out later in the day or the following morning.  
•    Working temperature of AlcoSense® PRECISION should be between 5° C to 40°C,
•    Storage temperature of AlcoSense® PRECISION should be -15°C to 65°C


LIABILITY FOR PROPER FUNCTION OR DAMAGE

The liability for proper functioning of the instrument is irrevocably transferred to the owner or operator to the extent that the instrument is serviced or repaired by personnel not employee or authorised by Andatech Pty Ltd.  Therefore, the warranty will be void.

EFFECTS OF ALCOHOL ON THE HUMAN BODY


Alcohol is a central nervous system depressant. This means that it slows down the processes occurring in the higher centres of the brain resulting in such classical symptoms as loss of balance, poor coordination of the eyes and limbs, tunnel vision, and inability to be self-critical, with the result that the drunken driver genuinely believes himself to be driving better and more safely than he or she really does.

WARRANTY


Manufacturer warrants for 1 year for the product to be free from defects in workmanship or material (excluding re-calibration) in normal service from the date of purchase.  Manufacturer’s obligation under this warranty is limited to replacing adjusting or repairing the unit if returned along with proof of purchase.  This warranty is void if the unit has been tampered with, damaged or abused in any way.

RECALIBRATION AND SERVICE


The AlcoSense® PRECISION uses a sensor to measure blood alcohol levels.  Depending upon the amount of alcohol registered by the sensor after a period of time, it will require a re-calibration.  If the AlcoSense precision is for heavy commercial use, the manufacturer recommends this is done every 6 months (or up to 500 uses).  For Normal use, calibration required every 6-12 months.

For recalibration and technical support, please contact us at:
Andatech Pty Ltd Hot line:
1300 800 200
Or
www.andatech.com.au

DISCLAIMERS


1.    This product must be used strictly in accordance with the instructions in this manual
2.    This product is intended to provide the user with an indication of alcohol on the breath. However, neither the manufacturer nor the supplier gives any warranty (express or implied) that the product can give any indication of blood alcohol level.
3.    A person's BAC (Blood Alcohol Concentration) can only be accurately measured by the administration of a blood test. This product only measures breath alcohol content which, in turn, only gives an approximate indication of blood alcohol concentration.
4.    In these circumstances the user of this product should not rely on the information provided thereby as an accurate indication of his blood alcohol concentration or of his level of intoxication or of his fitness to drive and in particular should not take any action in reliance on such information as the product can provide no more than an indication of alcohol on the breath.
5.    If the user of this product makes any decision or takes any action based on the use of the product such decision or such action shall be at the sole risk of the user and neither the manufacturer nor the supplier assumes any responsibility for such decision or action. In particular, neither the manufacturer nor the supplier shall be in any way liable if the user of the product asserts that the product led him to believe that he was fit to operate a motor vehicle and is subsequently found not to be so fit.

Service Centre

AUSTRALIA :

ANDATECH PTY LTD
PO BOX 3038
Nunawading VIC 3131

Ph : 1300 800 200
www.andatech.com.au